Electrochemical sensors

We offer production of customer design screen printed electrochemical sensors beside our standard products.

Starting Kit STK Starting kit is the set of twenty different electrochemical sensors to find the best one to fit your application. Starting kit contains 10 types of electrochemical sensors (2 sensors of each type), sensors connector KAs.S. and sensors box with numbered positions and silica gel. STK Datasheet  39 € 
AC1 AC1 The most used 3-electrode sensor with working, reference and auxiliary electrodes.  This sensor is used as a substrate for glucose oxidase or acetylcholine esterase biosensor preparation (AC1.GOD, AC1.AChE). AC1 Datasheet

1.4 €/pc min. 25pcs

 AC1. AChE

Acetylcholinesterase biosensor.       Acetylcholinesterase from electric eel type VI-S is immobilised on a w electro chemical sensor.orking electrode of AC1.W2.RS. The diameter of the immobilised bioactive membrane is 2 mm and the mean applied activity is 1 unit per mm².

 AC1.AChE Datasheet

4 €/pc min. 25pcs

   AC1. GOD

Glucose Oxidase biosensor. Glucose Oxidase (GOD) from Aspergillus Niger is immobilised on a working electrode of AC1.W2.RS electrochemical sensor. The diameter of the immobilised bioactive membrane is 2 mm and the mean applied activity is 1 unit per mm².

AC1.AChE Datasheet
 4 €/pc min. 25pcs

AC1P

AC1P
New type of the AC1P sensors (HIGH QUALITY SURFACE ELECTROCHEMICAL SENSOR) are formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. Working electrode has homogenous surface with roughness less than 1 μm. This specific AC1P sensors enable antibodies immobilization and nanostructures preparation.
AC1P Datasheet

7 €/pc  min. 5pcs

 MAC1 MAC1 The sensor MAC1 is formed on a corundum ceramic base. Onto this surface the working, the reference and the auxiliary electrodes are applied. The working and the reference electrodes are made of variety of materials. Active part of the sensor is placed in a small microreactor with lid. 
At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.
MAC1 Datasheet 

5 €/pc  up tp 250pcs

 

AC2

AC2 An electrochemical sensor with 2 working electrodes and 1 reference electrode allowing differential measurement of two signals at once. AC2 Datasheet

1.4€/pc  min. 25pcs

AC3

AC3
A narrow single working electrode sensor designed to replace metal electrodes made from expensive materials.

AC3 Datasheet

1.4 €/pc min. 20pcs

AC4

AC4
A single working electrode sensor with a bigger metal surface area compared to the AC3.  It may serve for metal coating. AC4 Datasheet

3 €/pc min. 25pcs

AC5

AC5
An array of 8 working electrodes.  Each electrode has its own reference electrode.  It is possible to measure eight signals at once.
AC5 Datasheet

6 €/pc min. 5pcs

AC6

AC6
An electrochemical sensor with 1 working, 1 reference and 2 auxiliary electrodes.
AC6 Datasheet

1.4 €/pc min. 25pcs

AC7

AC7
This sensor is a shorter version of the AC1.  It is intended for a different connector with soldered pins.
AC7 Datasheet

1.4 €/pc min. 25pcs

AC8

AC8 An electrochemical sensor with 4 working electrodes.  Some of them may be modified by enzyme, DNA, antibody, etc. for multi-analyte detection.  AC8 Datasheet

3 €/pc min. 10pcs

AC9

AC9 An electrochemical sensor with an array of 8 working electrodes and 1 common reference electrode.  It was designed as a biosensor substrate for multi-analyte detection.
 AC9 Datasheet

4 €/pc min. 5pcs

AC9C  AC9C The sensor is formed on a corundum ceramic base. On to this surface eight working electrodes, and the reference electrode are applied. The electrodes can be made of variety of materials. At the end of the sensor there is an integrated connector. It is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be put on the working electrodes of the sensor.  AC9C Datasheet 5 €/pc min. 5pcs

AC10

AC10
An electrochemical sensor with an array of 20 working electrodes and 1 common reference electrode.  It was designed for the complicated complex analysis of 20 analytes in one step.
 AC10 Datasheet

5 €/pc min. 5pcs

CC1

CC1
A Conductivity measurement sensor with finger structure of electrodes
CC1 Datasheet

1.4 €/pc min. 25pcs

CC2

CC2 A conductivity measurement sensor designed for differential measurements of conductivity on the background of another effect.
 CC2 Datasheet

1.4 €/pc min. 25pcs

Cells

MicroFlow System MFS The BVT Microflow System is designed to remove the conventional problems rising within the standard electrochemical measurement setup.  It allows noiseless stirring and regulated liquid flow onto the electrode surface, control of temperature and atmosphere.  The sensor chamber design is suitable for the AC1 sensor formats and permits easy replacement of used substrates.  The Microflow System is predominantly used for Batch Injection Analysis.
MFS Datasheet from 1550  €

FC2
Flow cell FC2 enables the use of AC1 and  CC1 sensors in a flow through arrangement.  The cell ensures the wall-jet flow around the working electrode and also contains  the contact and output cable. FC2 Datasheet 199

FC3 Flow cell FC3 enables the use of AC1, AP1 and CC1 sensor together with illumination of the working electrode.  Just below the working electrode there is an LED diode, which can be used to stimulate the processes on the working electrode.  The sensor is inserted into the body of the cell and tightened by closing the door.  This cell also contains  the contacts and output cable. FC3 Datasheet 299
FC9 FC9
Flow cell FC9 enables the use of the AC9 electrochemical array sensor in a flow through arrangement.  The sensor is inserted into the body of the cell and tightened by closing of the door.  This cell ensures a reproducible flow around all 8 working electrodes.  The principle is similar to a rotating disc electrode and the cell also contains the contact and output cable. FC9 Datasheet 1800
TC2 TC2
A simple glass cell for electrochemical measurements with a jacket which enables thermostat control.

TC2 Datasheet
54
TC3 TC3
A simple jacketed glass cell for electrochemical measurements with miniaturised classical electrode types WCE, RCE and ACE.  The cell has a lid with 4 holes to insert electrodes into the cell. TC3 Datasheet
54
TC4  TC4 Simple glass cell serves for electrochemical measurements. The temperature of the analysed solution can be controlled when placing the cell in TK-1 thermostat. Cell openings are designed for KSA1.* electrochemical sensors connector and stirrer or connector KA1.* and stirrer separately.  TC4 Datasheet  54
         

 

 Connectors

KA1 KA1
Connector KA1 enables the use of electrochemical sensors based on AC1, AC4, AC11, AP1, CC1, CC2 and TS1 substrates in a classical electrochemical arrangement within a stirred vessel.  Glass cell TC1 is recommended for use with the KA1.*
KA1 Datasheet 45
KA1s KA1s We have started production of new type of the connector KA1s.* which enables the use of the electrochemical sensors AC1, AC4, AC11, AP1, CC1, CC2 and TS1. This connector is much simpler, smaller and cheaper than his brother - version KA1.*
KA1 Datasheet

from

10

KA2 KA2
Connector KA2 enables the use of an eletrochemical sensors based on the AC2 substrate in a classical electrochemical arrangement within a stirred vessel.  Glass cell TC1 is recommended for use with the KA2.*
KA2 Datasheet 45
KSA1 KSA1
Connector + conic stirrer KSA1 enables the use of  electrochemical sensors / biosensors based on AC1, AC4, AP1, CC1, CC2 and TS1 substrates in a classical electrochemical arrangement within a stirred vessel.  Glass cell TC1 is recommended for use with the KSA1.*
KSA1 Datasheet 199
KA4 KA4
Connector KA4 enables the use of the electrochemical sensors / biosensors based on AC1, AC4, CC1, CC2 and TS1 substrates in a classical electrochemical arrangement.  This connector has 6 contacts.
The 3 contacts on the front side serve as contacts for the 3- electrode system.
The 3 contacts on the back side are for use with AC1 (H,T) sensors that possess heating and temperature reading functions.
Glass cell TC1 is recommended for use with the KA4.*
KA4 Datasheet 63
KA5 KA5 The connector enables the use of the electrochemical sensor AC5. KA5 Datasheet  77  
KA9s KA9c The connector enables the use of the electrochemical sensor AC9c or biosensor based on the AC9c substrate in classical electrochemical arrangement.  KA9c Datasheet 25

Pumps

2PP

2PP 2 channel Peristaltic pump 2PP*.* consists of a miniature motor with planetary gear and a stainless steel body.  Optionally the motor is equipped with an encoder.  The pump has 2 channels with the flow in one direction only.  It can be used in hand-held devices.  Tubing lifetime is optimised to maximal value.  Pulsation is minimised for flow cell FC2. 2PP Datasheet From 837

Peristaltic Pump

PP
Peristaltic pump PP*.* consists of a miniature motor with planetary gear and a stainless steel body.  Optionally the motor is equipped with an encoder.  The pump has 1 channel with the flow in one direction only.  It can be used in hand-held devices.  Tubing lifetime is optimised to maximal value.  Pulsation is minimised for flow cell FC2.
PP Datasheet From 708
Linear Pump LP
Linear pump LP.* consists of a miniature motor with a digital encoder and planetary gear within an aluminium pump body.  The motor drives a screw, which moves the piston for the syringe in both directions.  It can be used in hand-held devices.
The main advantage of the linear pump is that there is no pulsation and there is easy connection to the syringe piston by a magnet.  The pump can operate with flow cell FC2 and is delivered with an optional manual piston holder.
LP Datasheet 1500

Miscellaneous

 

TK1 TK1 Thermostat / Temperature Cycler TK1 is designed to control or cycle the temperature of samples in Eppendorf vials.  The temperature can be adjusted in 5 pre-programmed steps (-10, 0, 20, 25, 37) °C.  Alternatively other values can be selected via the keyboard. Desired and actual temperatures are measured. TK1 Data Sheet 1200
Biosensor Analyzer BA1 The Biosensor Analyzer BA1.* is a small compact amperometric analyzer designed for sensor and biosensors signal analysis. The operation is interactive using buttons Yes and No. The instructions as well as the results are displayed on a two-line alfanumerical display. The device is provided with a microprocessor and bi-directional communication with computer and with memory for data storage.The device can be used in field (internal accummulator) or in laboratory. The results can be displayed and evaluated on PC during measurement. The device is equipped with sophisticated program for biosensors signals evaluation
BA1 Data Sheet from 1185
Manual Screen Printer SP1 The Manual Screen Printer is useful for applying of biochemical paste on electrochemical sensors. It may be used for preparing customer design electrochemical sensors also. It uses extremely small quantities of printing material. With the adjustment of the distance between the screen andthe substrate the thickness of the printed elements can be varied. Under optimal conditions printing of lines with 200 μm can be achieved.
SP1 Data Sheet 3000 €
WCE WCE
The Working Classic Electrode (WCE) is a hollow glass tube with a Pt or Au wire inside.  The diameter of the metal wire is selectable in a range between 1 μm - 2000 μm.  Only the circle glossy area of the metal wire is outside the glass tube.  The WCE is designed for measurements with the TC3 thermostatic cell.  Standard cable length of the WCE is 1.5m and the connector, or banana plug, colour is red.
WCE Datasheet

from

95

RCE

RCE
The Reference Classic Electrode (RCE) is a hollow glass tube with silver or silver covered by silver chloride wire inside.  The tube is hollow with a hole in the wall for inserting KCl solution. The hole is covered by a rubber band and the RCE is designed for measurements with the TC3 thermostatic cell.  Standard cable length of the RCE is 1.5m and the connector, or banana plug, colour is yellow.
RCE Datasheet 95
ACE
ACE
The Auxiliary Classic Electrode (ACE) is a hollow glass tube with a platinum plate wire.  It is designed for measurements with the TC3   thermostatic cell.  Standard cable length of the ACE is 1.5m and the connector, or banana plug, colour is black.
ACE Datasheet 95
OE1 OE1 The miniature Oxygen electrode (OE) consists of a stainless steel body, platinum electrode, silver reference electrode and membrane holder. The platinum electrode is melted in glass. The membrane holder with electrolyte is attached by thread. ACE Datasheet
250 
 

 

Catheters

PME011

PME011

 

Microdialysis catheter PME011 is provided with a special membrane which produces a "plasma-like" sample without the need for blood centrifugation. It enables "plasma-like" samples taking and continuous monitoring of low-molecular substances in circulating blood without withdrawing blood from the patient. It offers virtually real-time information. Samples can be collected for off-line analysis if required. This catheter is easy to use and reduces risks of contact with blood borne pathogens. The MicroEye is intended for intravenous use for periods up to 48 hours and is inserted via 18G blood catheter.

 

150 €

Brochure PME011

MDC1

MDC1

 

MICRODIALYSIS CATHETER FOR "IN VITRO" MEASUREMENT - MDC1, new device developed in cooperation with Probe Scientific, Ltd., UK, integrates the microflow cell FC2 (BVT Technologies a.s.) interconnected with microdialysis catheter PME011 (Probe Scientific, Ltd., UK). MDC1 enables continuous monitoring of low-molecular substances in circulating blood without withdrawing blood from the testing animal. (The device is not approved for human use as a whole; the microdialysis catheter has the approval for medical use). The device can be also used for measurement in fermentation reactors, in subcutaneous tissues or in special scientific apparatuses. The main advantage of this catheter is in a special membrane which produces a "plasma-like" or "prefiltered" sample without the need for blood centrifugation or deproteinization. MDC1 makes online monitoring of different blood parameters (biochemical compounds actual concentration or kinetics of enzymatic reactions) possible. The device is also convenient for pharmacological studies. The device can be used only for non human applications.

 

350 €

Brochure MDC1


Orders, queries: Oldřiška Mojžíšová

Oldriska Mojzisova

E-mail: info (at) bvt.cz
Tel.: + 420 541 513 545
Fax: + 420 541 513 665
Hudcova 78c, 612 00 BRNO
Czech Republic