Starting kit is the set of twenty different electrochemical sensors to find the best one to fit your application. Starting kit contains 10 types of electrochemical sensors (2 sensors of each type), sensors connector KA1s.S. and sensors box with numbered positions and silica gel.
39 €
AC1
The most used 3-electrode sensor with working, reference and auxiliary electrodes. This sensor is used as a substrate for glucose oxidase or acetylcholine esterase biosensor preparation (AC1.GOD, AC1.AChE).
1.9 €/pc min. 25pcs
AC1. AChE
Acetylcholinesterase biosensor. Acetylcholinesterase from electric eel type VI-S is immobilised on a w electro chemical sensor. Working electrode of AC1.W2.RS. The diameter of the immobilised bioactive membrane is 2 mm and the mean applied activity is 1 unit per mm².
4 €/pc min. 25pcs
AC1. GOD
Glucose Oxidase biosensor. Glucose Oxidase (GOD) from Aspergillus Niger is immobilised on a working electrode of AC1.W2.RS electrochemical sensor. The diameter of the immobilised bioactive membrane is 2 mm and the mean applied activity is 1 unit per mm².
4 €/pcmin. 25pcs
AC1P
New type of the AC1P sensors (HIGH QUALITY SURFACE ELECTROCHEMICAL SENSOR) are formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. Working electrode has homogenous surface with roughness less than 1 μm. This specific AC1P sensors enable antibodies immobilization and nanostructures preparation.
7 €/pcmin. 5pcs
MAC1
The sensor MAC1 is formed on a corundum ceramic base. Onto this surface the working, the reference and the auxiliary electrodes are applied. The working and the reference electrodes are made of variety of materials. Active part of the sensor is placed in a small microreactor with lid. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.
2.5 €/pcmin. 25pcs
AC2
An electrochemical sensor with 2 working electrodes and 1 reference electrode allowing differential measurement of two signals at once.
1.9€/pcmin. 25pcs
AC3
A narrow single working electrode sensor designed to replace metal electrodes made from expensive materials.
3 €/pcmin. 20pcs
AC4
A single working electrode sensor with a bigger metal surface area compared to the AC3. It may serve for metal coating.
17 €/pcmin. 25pcs
AC5
An array of 8 working electrodes. Each electrode has its own reference electrode. It is possible to measure eight signals at once.
21 €/pcmin. 5pcs
AC6
An electrochemical sensor with 1 working, 1 reference and 2 auxiliary electrodes.
2.5 €/pcmin. 25pcs
AC7
This sensor is a shorter version of the AC1. It is intended for a different connector with soldered pins.
1.9 €/pcmin. 25pcs
AC8
An electrochemical sensor with 4 working electrodes. Some of them may be modified by enzyme, DNA, antibody, etc. for multi-analyte detection.
4.5 €/pcmin. 10pcs
AC9
An electrochemical sensor with an array of 8 working electrodes and 1 common reference electrode. It was designed as a biosensor substrate for multi-analyte detection.
7.7 €/pcmin. 5pcs
AC9C
The sensor is formed on a corundum ceramic base. On to this surface eight working electrodes, and the reference electrode are applied. The electrodes can be made of variety of materials. At the end of the sensor there is an integrated connector. It is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be put on the working electrodes of the sensor.
11 €/pc min. 5pcs
AC10
An electrochemical sensor with an array of 20 working electrodes and 1 common reference electrode. It was designed for the complicated complex analysis of 20 analytes in one step.
27 €/pcmin. 5pcs
AC13
The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.
4.5€/pc
min. 10pcs
CC1
A Conductivity measurement sensor with finger structure of electrodes
3.5 €/pcmin. 25pcs
CC2